 Approved by: Checked by: Issued by:
SPECIFICATION
PRODUCT: SAW FILTER MODEL: HB4404D (X6941D) SIP5D
HOPE MICROELECTRONICS CO.,LIMITED
Tel:+86-755-82973806 Fax:+86-755-82973550
E-mail: sales@hoperf.com http://www.hoperf.com
Page 1 of 1
1.Construction
1.1 Dimension and materials Type : B4404D
1.2. Circuit construction, measurement circuit
2.Characteristics
Standard atmospheric conditions Unless otherwise specified , the standard rang of atmospheric conditions for making measurements and tests is as follows; Ambient temperature : 15 to 35 Relative humidity : 25% to 85% Air pressure : 86kPa to 106kPa
1
Operating temperature rang Operating temperature rang is the rang of ambient temperatures in which the filter can be operated continuously. -10 ~ +60 Storage temperature rang Storage temperature rang is the rang of ambient temperatures at which the filter can be stored without damage. Conditions are as specified elsewhere in these specifications. -40 ~ +70 Reference temperature +25
2.1 Maximum Rating DC voltage VDC 12 V Between any terminals AC voltage Vpp 10 V Between any terminals 2.2 Electrical Characteristics Source impedance Zs=50 Load impedance ZL=2k//3pF and matching network TA=25 Item Freq min typ max Center frequency Fo 44.00 MHz Insertion attenuation 44.00MHz 17.7 19.7 21.7 dB Reference level
Amplitude ripple (p-p)
41.60 ... 46.40 MHz 40.75MHz 41.31MHz 41.43MHz Relative attenuation 41.60MHz 46.40MHz 46.57MHz 46.69MHz 47.25MHz 35.00~39.10MHz 39.10~40.35MHz Sidelobe 47.65~48.65MHz 48.65~55.00MHz Temperature coefficient
0.5 25.0 0.6 -0.9 -0.7 -0.7 -0.7 0.8 25.0 32.0 26.0 24.0 30.0 32.0 1.6 0.3 0.1 0.1 0.6 2.0 36.0 40.0 32.0 30.0 37.0 -18 2.6 1.5 0.8 0.8 1.5 3.2 -
dB dB dB dB dB dB dB dB dB dB dB dB dB ppm/k
2
2.3 Environmental Performance Characteristics Item Test condition Allowable change of absolute Level at center frequency(dB) High temperature test < 1.0 70 1000H Low temperature test < 1.0 -40 1000H Humidity test < 1.0 40 90-95% 1000H Thermal shock < 1.0 -20==25==80 20 cycle 30M 10M 30M Solder temperature test < 1.0 Sold temp.260 for 10 sec. Soldering More then 95% of total Immerse the pins melt solder area of the pins should be covered with solder at 260+5/-0 for 5 sec. 2.4 Mechanical Test Item Test condition Vibration test 600-3300rpm amplitude 1.5mm 3 directions 2 H each Drop test On maple plate from 1 m high 3 times Lead pull test Pull with 1 kg force for 30 seconds Lead bend test 90o bending with 500g weigh 2 times 2.5 Voltage Discharge Test Item Test condition Surge test Between any two electrode
Allowable change of absolute Level at center frequency(dB) <1.0 <1.0 <1.0 <1.0
Allowable change of absolute Level at center frequency(dB)
<1.0
3


▲Up To Search▲   

 
Price & Availability of HB4404D

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X